P0135 Oxygen sensor heater circuit malfunction ( Bank 1 Sensor 1)
P0753 Problem in shift solenoid valve A circuit
When P0753 set check the solenoid connection, this can also be a faulty shift solenoid As for P0135 this is more than likely a degrade 02 sensor ,
P0753 a open circuit with the shift solenoid will set this code condition check the connection