0 like 0 dislike
2.3k views
by

The car runs normally, but has failed inspection due to DTCs P0411 and P2431. From my current research, it would appear that this is being caused either by a damaged vacuum hose, or by a faulty ASV. I have no current diagrams to where these components may be located. Any thoughts to accuracy of diagnosis or assistance locating the components would be appreciated.

Vehicle: 2007 Saturn ION

1 Answer

0 like 0 dislike
by (13.5k points)

P0411 Secondary air injection system incorrect flow detected

P2431 Secondary air injection system pressure sensor A circuit range / performance

This is more of a faulty secondary air pump, The air pump is for emission on cold start up to rapidly warm up the catalytic convertor thus lowering emission. Check also the relay or replace the relay for the airpump.The most the airpump is on is 1 minute during cold start up, so you can expect internal failure of the air pump.Due to the enviroment that it at.