P1163 2002 NISSAN ALTIMA SEDAN - Heated Oxygen Sensor 1 Lean Shift Monitoring Bank 2

Repair Importance Level: 3/3
Repair Difficulty Level: 2/3   
Comments  |  Add Comment

Possible causes

  • Faulty Front Heated Oxygen Sensor Bank 2
  • Faulty Front Heated oxygen sensor 1 heater
  • Fuel pressure
  • Faulty Fuel Injectors
  • Intake air leaks

Tech notes

If there are no intake air leaks, the most likely cause of the P1163 code is the front O2 sensor bank 2.

When is the code detected?

The maximum and minimum voltage from the sensor are not reached to the specified voltages.

Possible symptoms

  • Engine Light ON (or Service Engine Soon Warning Light)

P1163 2002 Nissan Altima Sedan Description

The heated oxygen sensor 1 is placed into the front tube. It detects the amount of oxygen in the exhaust gas compared to the outside air. The heated oxygen sensor 1 has a closed-end tube made of ceramic zirconia. The zirconia generates voltage from approximately 1V in richer conditions to 0V in leaner conditions. The heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts the injection pulse duration to achieve the ideal air-fuel ratio. The ideal air-fuel ratio occurs near the radical change from 1V to 0V.
OBDII Code P1163 2002 Nissan Altima Sedan - Heated Oxygen Sensor 1 Lean Shift Monitoring Bank 2 - AutoCodes.com

Need more help?

Get the P1163 2002 Nissan Altima Sedan code diagnosed by a professional: Find a repair shop in your area

Related Information

P1163 2002 NISSAN ALTIMA SEDAN Comments

Help us improve AutoCodes.com. Leave a comment below or tell us if the information above help you fix the code. What are the symptoms on your vehicle for the P1163 2002 Nissan Altima Sedan code? Have you replaced any parts?
Any information is appreciated. Thanks
Top ⇧