AutoCodes
 
OBDII Code List
 
P1147 2002 NISSAN ALTIMA SEDAN

P1147 2002 NISSAN ALTIMA SEDAN - Heated Oxygen Sensor 2 Maximum Voltage Monitoring Bank 1

Repair Importance Level: 3/3
Repair Difficulty Level: 2/3   
Comments  |  Add Comment

P1147 2002 NISSAN ALTIMA SEDAN Possible Causes

  • Faulty heated oxygen (O2) sensor 2 (rear)
  • Intake air leaks
  • Heated oxygen (O2) sensor 2 (rear) harness is open or shorted
  • Heated oxygen (O2) sensor 2 (rear) circuit poor electrical connection
  • Inappropriate fuel pressure
  • Faulty fuel injectors

First diagnose P1147 2002 NISSAN ALTIMA SEDAN code

    Check the "Possible Causes" listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded terminals.

P1147 2002 NISSAN ALTIMA SEDAN Tech Notes

Replacing the O2 Sensor 2 usually takes care of the problem

Cost of diagnosing the P1147 2002 NISSAN ALTIMA SEDAN code

    Labor: 1.0

    The cost of diagnosing the P1147 2002 NISSAN ALTIMA SEDAN code is 1.0 hour of labor. The auto repair labor rates vary by location, your vehicle's make and model, and even your engine type. Most auto repairs shops charge between $75 and $150 per hour.

When is the P1147 2002 NISSAN ALTIMA SEDAN code detected?

The P1147 code is triggered when the maximum voltage from the sensor is not reached to the specified voltage.

P1147 2002 NISSAN ALTIMA SEDAN Possible Symptoms

  • Engine Light ON (or Service Engine Soon Warning Light)
  • Possible high fuel consumption
  • Possible excessive smoke from exhaust

P1147 2002 Nissan Altima Sedan Description

The Heated Oxygen Sensor 2 (HO2S) (Rear O2 Sensor), after three way catalyst (manifold), monitors the oxygen level in the exhaust gas on each bank. For optimum catalyst operation, the air fuel mixture (air-fuel ratio) must be maintained near the ideal stoichiometric ratio. The HO2S output voltage changes suddenly in the vicinity of the stoichiometric ratio. The Engine Control Module (ECM) adjusts the fuel injection time so that the air-fuel ratio is nearly stoichiometric. The HO2S generates a voltage between 0.1 and 0.9 V in response to oxygen in the exhaust gas. If the oxygen in the exhaust gas increases, the air-fuel ratio becomes Lean. The ECM interprets Lean when the HO2S voltage is below 0.45 V. If the oxygen in the exhaust gas decreases, the air-fuel ratio becomes Rich. The ECM interprets Rich when the HO2S voltage is above 0.45 V.
OBDII Code P1147 2002 Nissan Altima Sedan - Heated Oxygen Sensor 2 Maximum Voltage Monitoring Bank 1 - AutoCodes.com

P1147 2002 NISSAN ALTIMA SEDAN More Information

Need more information on how to fix the P1147 2002 NISSAN ALTIMA SEDAN code?
Get Access to Factory Service Manuals

Need more help?

Get the P1147 2002 Nissan Altima Sedan code diagnosed by a professional: Find a repair shop in your area

Related Information

P1147 2002 NISSAN ALTIMA SEDAN Comments

Help us improve AutoCodes.com. Leave a comment below or tell us if the information above help you fix the code. What are the symptoms on your vehicle for the P1147 2002 Nissan Altima Sedan code? Have you replaced any parts?
Any information is appreciated. Thanks
Top ⇧