P0ADA - Hybrid Battery Positive Contactor Control Circuit Range/Performance

Repair Importance Level: 3/3
Repair Difficulty Level: 3/3   
Comments  |  Add Comment

Possible causes

  • Faulty System Main Relay
  • System Main Relay harness is open or shorted
  • System Main Relay circuit poor electrical connection
  • Faulty HV control ECU

Possible symptoms

  • Engine Light ON (or Service Engine Soon Warning Light)

P0ada Description

The SMRs (System Main Relays) connect and disconnect the high-voltage power supply circuit in accordance with requests from the HV control ECU. To ensure a reliable operation, they consists of a total of 3 relays (1 for the negative side and 2 for the positive side).

To connect, SMR1 and SMR3 turn ON initially. Then, SMR2 turns ON and SMR1 turns OFF. This process protects the circuit from the high-voltage surge current by allowing the limit current to flow via the resistor.

To disconnect, SMR2 and SMR3 turn OFF in that order. The HV control ECU checks that the relays have turned OFF properly.

The HV control ECU monitors the proper operation of the SMRs (CON1, CON2 and CON3) to check for a malfunction.

OBDII Code P0ada - Hybrid Battery Positive Contactor Control Circuit Range/Performance - AutoCodes.com

P0ADA Information for specific makes

  • P0ADA LEXUS Hybrid Battery Positive Contactor Control Circuit Range/Performance
  • P0ADA NISSAN Hybrid Battery Positive Contactor Control Circuit Range/Performance
  • P0ADA TOYOTA Hybrid Battery Positive Contactor Control Circuit Range/Performance

Need more help?

Get the P0ada code diagnosed by a professional: Find a repair shop in your area