Diagnostic guide for P1518

Diagnostic Guide for P1518 - Intake Manifold Runner Control Stuck Open

The P1518 code indicates that the Intake Manifold Runner Control (IMRC) is stuck open when it should be closed. This guide aims to help you diagnose the underlying issues causing this code, ensuring proper function of the IMRC system.

Difficulty
Intermediate
Estimated Time
30-60 Minutes
$
Estimated Diagnostic Cost
$0-$100
Typical shop charge to perform this diagnostic process. Repair parts and labor are not included.
Tools Needed
OBDII scanner, multimeter, basic hand tools, vacuum gauge
!
Safety Notes
Ensure the engine is cool before working on the intake system. Disconnect the battery when working on electrical components. Use caution when handling tools around moving parts.
Step 1

Scan for Codes

Instruction Use an OBDII scanner to check for any stored trouble codes in the PCM. Note any additional codes that may be present.
Expected result The scanner displays the P1518 code along with any other codes.
If Pass If P1518 is the only code, proceed to the next step. If there are other codes, investigate those first as they may be related.
If Fail If no codes are found, ensure the scanner is functioning properly and recheck the connection to the vehicle's OBDII port.
Ask Coddy about this step
Coddy can help with this step only. Tell me what you tested or what result you got.
Step 2

Inspect the IMRC Actuator and Wiring

Instruction Visually inspect the IMRC actuator and its wiring for any signs of damage, corrosion, or loose connections.
Expected result The actuator and wiring should appear intact without any visible damage.
If Pass If everything looks good, proceed to test the actuator's electrical function.
If Fail If damage is found, repair or replace the affected components before retesting.
Ask Coddy about this step
Coddy can help with this step only. Tell me what you tested or what result you got.
Step 3

Test the IMRC Actuator Functionality

Instruction Using a multimeter, check the resistance of the IMRC actuator. Compare the reading to the manufacturer's specifications.
Expected result The resistance reading should fall within the specified range.
If Pass If the resistance is within range, the actuator is likely functioning correctly. Proceed to check the PCM signal.
If Fail If the resistance is out of range, the actuator may be faulty and should be replaced.
Ask Coddy about this step
Coddy can help with this step only. Tell me what you tested or what result you got.
Step 4

Check the PCM Signal to the Actuator

Instruction With the engine running, use the multimeter to check for voltage at the actuator connector while commanding the IMRC to open and close via the scanner.
Expected result You should see a change in voltage corresponding to the commands sent to the actuator.
If Pass If the voltage changes as expected, the PCM is functioning correctly. Proceed to test for vacuum operation.
If Fail If there is no voltage change, the PCM may be faulty or there may be an issue with the wiring harness.
Ask Coddy about this step
Coddy can help with this step only. Tell me what you tested or what result you got.
Step 5

Test the Vacuum Operation

Instruction Check the vacuum supply to the IMRC actuator using a vacuum gauge. Ensure that the vacuum solenoid is functioning properly.
Expected result The vacuum gauge should indicate proper vacuum levels when the solenoid is energized.
If Pass If vacuum levels are correct, the issue may lie within the actuator itself. Consider replacement.
If Fail If there is no vacuum, inspect the vacuum lines and solenoid for blockages or failures.
Ask Coddy about this step
Coddy can help with this step only. Tell me what you tested or what result you got.